Water in orbit

By University of Utah
Tuesday, 01 December, 2009


Space is not a fun place to get a stomach bug. To ensure drinking water is adequately disinfected, University of Utah chemists have developed a two-minute water quality monitoring method that just started six months of tests aboard the International Space Station.

The new method involves sampling space station or space shuttle galley water with syringes, forcing the water through a chemical-imbued, disk-shaped membrane and then reading the colour of the membrane with a commercially available, handheld colour sensor, normally used to measure the colour and glossiness of automobile paint.

The sensor detects if the drinking water contains enough iodine (used on US spacecraft) or silver (used by the Russians) to kill any microbes. The International Space Station has both kinds of water purification systems.

This NASA C-9 research aircraft climbs steeply before levelling out and then diving. Such planes, nicknamed ‘vomit comets’, fly 40 such arcs each flight, creating weightless conditions at the top of each arc. A University of Utah drinking water quality monitoring system was developed during such flights and now is being tested on the International Space Station.

Marc Porter, a University of Utah professor of chemistry and chemical engineering, explains: “Currently they bring water back on the space shuttle and analyse it on the ground. The problem is there is a big delay. YouÂ’d like to be able to maintain iodine or silver [disinfectant] levels in real time with an onboard monitor.

“Our focus was to develop a small, simple, low-cost testing system that uses a handheld device, doesn’t consume materials or generate waste, takes minimal astronaut time, is safe and works in microgravity.”

As a spin-off, the test is being modified so it can quickly check water for the level of arsenic - a natural pollutant in places like Bangladesh and the US Southwest and Northeast - and it can be adapted to quickly, inexpensively test for other pollutants.

“It is a general method,” says Lorraine Siperko, a senior research scientist in Porter’s laboratory. “It could be used on the ground for testing all kinds of water contaminants such as arsenic, chromium, cadmium, nickel and other heavy metals.”

The method is easy to use and much cheaper than existing tests, says Porter.

Keeping it clean

The project began a decade ago, before Porter joined the Utah faculty, when NASA sought proposals for disinfectant or ‘biocide’ monitors to check the safety of drinking water on manned spacecraft.

“You can’t sterilise water well enough to keep things from growing in it,” Porter says. “Nature happens.”

 

 

As part of an effort to develop a system for monitoring the cleanliness of drinking water in space, researchers first conducted experiments on how to minimise bubbles in water samples, in weightless conditions. Shown here is a dyed water sample with bubbles during the weightless portion of a flight aboard a NASA research airplane. The water quality monitoring system - developed by Marc Porter, a University of Utah chemist - was delivered to the International Space Station in August for six months of testing.

NASA uses iodine as a disinfectant on US spacecraft. The Russians use colloidal silver - pure silver nanoparticles, some of which go into solution.

The problem for both iodine and silver is that microbes grow in the water if levels are too low. If levels are too high, iodine-treated water tastes bad and eventually might cause thyroid problems, and silver at excessive levels can turn the skin greyish blue.

Space station water now is sampled and returned to Earth for testing at intervals of months because “they don’t have an acceptable onboard technique,” Porter says.

 

After space shuttle Discovery launched on 28 August, it delivered to the International Space Station a water quality monitoring kit developed by University of Utah chemists. Part of the kit, which is the size of a small ice chest, is shown here, with two commercially available colour sensors that will be used during six months of testing to check for levels of the disinfectants iodine and silver in space station drinking water.

He says the space station is a proving ground for technologies for longer manned flights to the moon and Mars - even though those flights are unlikely anytime soon due to high costs and other priorities.

Water for astronauts is carried into orbit and also produced on the space station as a by-product of hydrogen and oxygen reacting in fuel cells. Disinfectants or biocides are added during flight, but actual levels in drinking water cannot be tested until samples are brought back to Earth. Porter says required biocide levels in drinking water are 0.1 to 1 part per million silver and 0.1 to 5 parts per million iodine.

Riding the ‘Vomit Comet’

The water-monitoring system fits in a pack the size of a small ice chest. It was launched on 28 August on the space shuttle Discovery, bound for the International Space Station.

The project is funded by the National Aeronautics and Space Administration, the Utah Science, Technology and Research (USTAR) economic development initiative and two universities where Porter worked previously: Arizona State and Iowa State.

The project team now includes NASA, USTAR and the University of Utah, Iowa State University and Wyle Laboratories. Porter is a professor hired under the USTAR program.

 

University of Utah chemist Lorraine Siperko experiences weightlessness during a flight aboard a NASA ‘vomit comet’ aircraft. Siperko made several such flights to test a new system designed to monitor drinking water quality aboard spacecraft. The system includes a commercially available colour sensor (blue device in foreground) that checks the level of disinfectant in drinking water. The water quality monitoring system was delivered to the International Space Station in August for six months of tests.

During the past decade, the water quality monitoring method was developed and tested during about two dozen low-gravity flights on NASA’s ‘vomit comets’ - research aircraft such as the KC-135 and C-9, which took off from Ellington Air Force Base in Texas. During a flight, each plane makes 40 parabolic arcs through the sky, climbing steeply, then levelling and diving. Weightless conditions exist for about 30 seconds at the top of each arc.

Porter rode the KC-135 twice in 2002 and 2004 and became very motion sick. Siperko rode the C-9 five times in 2006 and 2007, developing and testing the water-quality monitoring technique, including how to remove drinking water samples from collection bags without excessive bubbles, which don’t easily separate from water in weightless conditions. The handheld sensor and chemicals used in the testing process were also checked for reliability during the low-gravity plane flights.

Now, “the experiment is in space for the first time,” Siperko says. “It’s very rewarding and exciting to know that something you worked on is so important that NASA put it on the shuttle for a six-month test on the International Space Station.”

Porter called the space station “the coolest place to do experiments.”

On the space station, “once per month they will check the water for iodine and silver,” Siperko says “That data will be downloaded and relayed back to Earth, to Johnson Space Center,” in Texas.

“We have teleconferences with them and they will transfer the data to us electronically for us to look at,” she adds. “That way we can judge if the experiment is working correctly. If any unforeseen problems arise, then we can advise them as to what we think might be the problem and how to correct it.”

How it works

To test whether drinking water is adequately disinfected, space station astronauts will collect galley water in sealed plastic bags and then use syringes to remove some water from the bags and push it through a cartridge that contains a 1 cm diameter, polymer, porous-membrane disk impregnated with a chemical to detect either iodine or silver. The disks, known as ‘solid phase extraction membranes’, capture either iodine or silver, depending on the chemical in the disk.

 

University of Utah chemist Lorraine Siperko works on a water quality monitoring system while experiencing weightless conditions at the top of an arc-shaped flight path by a NASA C-9 research plane nicknamed the ‘vomit comet’. Other scientists working on the project include Bob Lipert of Iowa State University (left) and John Straub of Wyle Laboratories.

Next, the bottom half of the cartridge, which contains the disk, is placed against a German company’s handheld ‘diffuse reflectance spectrometer’ which shines light on the disk so it can read the disk’s colour in about two seconds. Porter says the device was developed to measure the reflectivity or gloss, and thus the quality, of finishes such as automotive paint, industrial surfaces, stainless steel and decorative metals.

Each handheld device - two are in the kit taken to the space station - weighs 0.5 kg, runs on four AA batteries, has a readout screen and measures 17.8 x 9.4 x 8.1 cm.

To test for iodine, the disk is impregnated with PVP (polyvinylpyrrolidone), a non-toxic chemical in contact lens cleaning solutions. The PVP reacts with iodine and the intensity of the resulting yellow colour reveals the concentration of iodine in the water.

To test for silver in water, the disk is imbued with DMABR, which is short for 5-(dimethylaminobenzylidene)rhodanine. A yellowish colour indicates silver is absent, while flesh to brighter pink reveals how much silver is present.

“We can do this whole analysis in about two minutes on the ground or in space,” Porter says.

Related Articles

Scientists unveil genomic 'tree of life' for flowering plants

The genomic tree sheds new light on the evolutionary history of flowering plants and their rise...

Found: the most massive stellar black hole in the Milky Way

With a mass 33 times that of the Sun, and based a mere 1926 light-years away, Gaia BH3 is the...

Astronauts will soon grow plants on the Moon

When humans take their first steps back on the Moon after 50 years during the Artemis III...


  • All content Copyright © 2024 Westwick-Farrow Pty Ltd